The details below would be a typical specification for our American Engineered Walnut Flooring. The word document you can download here can be saved on your own computer, amended and copied and pasted to any specification, bills of quantity or as part of the design build contract. To get the full details of any product just enter the product code like E124 in the search facility and it will give you all you need to complete the document that you can download. Our Industrial finishes are the best.
Preparation: Clean, Dry substrate with a moisture content of less than 10%
Wood boards: Free from decay, through splits and insect attack (including ambrosia beetle damage, unless permitted in the class/ grade specified).
Manufacturer: The Solid Wood Flooring Company – Tel: 01453 844 675 / mobile: 07831 680 206 / Email: info@thesolidwoodflooringcompany.com
Product reference: E502
Species: Engineered American Walnut
Appearance class/ Grade: To BS EN 942, ABCD Grade with sound knots up to 50mm permitted
Board size: 190mm wide 21mm thick with a solid 6mm top layer in lengths of 1860mm with two boards 600mm plus
Edges: Long edges tongued & grooved, Ends tongued & grooved.Bottom of long edges:
Finish: Finished in WOCA natural oil – as delivered
Moisture content at time of laying: 6-8%.
Laying: Flooring to be fitted in accordance with BS 8201:2011 Code of Practice for Flooring of Timber, Timber Products and wood based panel products
Pattern: As laid.
Adhesive: Bona R850 adhesive. Solid bed using 3mm notched trowel
Method of finishing: Prefinished boards with builders clean.
Other requirements:
Expansion gaps: A 10mm expansion is gap required around the perimeter of the floor and/or where the wood flooring meets differing materials. 8mm expansion gaps should be designed into the floor at a minimum of 6 – 8 Lm in any one direction and construction joints should not be bridged.
DPM: As designed into the floor
Performance: Load bearing: Conform to BS 6399-1: 1966 table 1 section 3 Reaction to fire: Perform to EN 13501-1 Dn s1
Slip Resistance: Tested to BS 7967-2: 2002 (Pendulum Test) and achieve LOW Slip risk in the DRY and MODERATE risk in the WET
PREPARATION OF SUBSTRATES
210 DRYNESS OF CONCRETE/ SCREED SUBSTRATES Relative humidity above substrate when tested with a hygrometer to BS 8201, Appendix A (maximum): 75%.
Test points: All corners, around perimeter, and random points over area being tested.
Drying aids: Turned off for not less than 4 days before testing.
220 CONCRETE/ SCREED SUBSTRATES
Finished surface: Smooth, even, and free from abrupt changes in level. Apply suitable smoothing compound, as necessary.
Surface regularity when checked with a 3 m straightedge with 3 mm feet at each end, placed
anywhere on the surface: No gap greater than 6 mm, and straightedge not obstructed by the
substrate.
Primer: If recommended by adhesive manufacturer, apply and allow to dry thoroughly before laying flooring.
590 PROTECTION
Protective covering: Submit proposals – Remove at completion.